{"title":"Surge Arrestors","description":"\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSurge Arrestors \u0026amp; Surge Protection Devices (SPDs)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eProtect your solar investment from lightning strikes and grid surges. Gauteng and the Highveld have some of the highest lightning activity in the world, and one surge can destroy an inverter, a battery management system or the electronics in your home.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eWe stock DC surge arrestors for the PV array side, in 600V and 1000V, Type II and combined Type I+II. They are DIN-rail mounted, with replaceable cartridges and a visual status indicator.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eCorrect surge protection is part of a compliant installation under SANS 10142-1. It can also matter for inverter warranty claims and insurance cover.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eNot sure which arrestor you need? Contact our team and we’ll match it to your system.\u003c\/p\u003e","products":[{"product_id":"surge-protection-spd-pv-dc-type-ii-600v-bud-40-2","title":"ZjBeny Surge Protection (SPD) PV DC Type II 600v BUD-40\/2","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eZJBeny Surge Arrestor 600V BUD-40\/2 Type II \u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0763\/7835\/files\/ZJBeny_logo_100x100.png?v=1571776457\" alt=\"ZJBeny Logo\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003ePV DC BUD-40\/2 Surge Protection Device was designed and manufactured, complying with the PV standard EN50539-11. It is widely used in PV DC combiner box, inverter, controller and PV DC cabinet. Rated voltage 600V DC. Maximum discharge current 40KA, High Energy Varistor, highly effective for lightning protection. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for use in all Photovoltaic Systems\u003c\/li\u003e\n\u003cli\u003ePrewired Modular Complete Unit, consisting of a Base Part and Plug-in Protection\u003c\/li\u003e\n\u003cli\u003ePlug-in Protection module, easy installation and maintenance\u003c\/li\u003e\n\u003cli\u003eHigh Energy Varistor. Response time less than 25 nanosecond\u003c\/li\u003e\n\u003cli\u003eOptimal remote signalling Contact (FM) for monitoring device (Floating Changeover Contact)\u003c\/li\u003e\n\u003cli\u003eDin Rail Mounting TH35-7.5\/DIN35\u003c\/li\u003e\n\u003cli\u003eComply with: EN50539-11\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ZJ Beny","offers":[{"title":"Default Title","offer_id":44279904993529,"sku":"AC-SA-ZJ-DC-2P-600-II","price":445.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0763\/7835\/products\/ZjBeny_SPD_600v_600_x_600_FO.png?v=1571776021"},{"product_id":"zjbeny-surge-protection-spd-pv-dc-type-i-ii-1000v-bud-s1000","title":"ZjBeny Surge Protection (SPD) PV DC Type I+II 1000v BUD-S1000","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eZjBeny Surge Protection (SPD) PV DC Type I+II 1000v BUD-S1000 \u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0763\/7835\/files\/ZJBeny_logo_100x100.png?v=1571776457\" alt=\"ZJBeny Logo\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003ePV DC BUD-S1000 Surge Protection Device was designed and manufactured, complying with the newest PV Standard IEC 61643-31. It is widely used in PV DC combiner box, inverter, controller and PV DC cabinet. Rated voltage 1000V DC. Maximum discharge current 30KA, High Energy Varistor, highly effective for lightning protection. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuitable for use in all Photovoltaic Systems\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eType 1+2 DC SPD for 1000V solar photovoltaic application\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThermal disconnect for fault indication\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRemote signal contact for options\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRoHS material\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eDin Rail Mounting TH35-7.5\/DIN35\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAccording to IEC 61643-31:2018\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable cellspacing=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd valign=\"top\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"211\"\u003e\n\u003cp\u003e\u003cspan\u003eBUD-S1000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003eNumber of ports\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"211\"\u003e\n\u003cp\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003eSPD according to IEC 61643-31\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"211\"\u003e\n\u003cp\u003e\u003cspan\u003eType 1+2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003eMax PV Voltage (DC+ --\u0026gt; DC-) Ucpv\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"211\"\u003e\n\u003cp\u003e\u003cspan\u003e≤1000V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003eMax PV Voltage (DC+ \/DC- --\u0026gt; PE) Ucpv\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"211\"\u003e\n\u003cp\u003e\u003cspan\u003e≤7250V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003eShort-circuit current rating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"211\"\u003e\n\u003cp\u003e\u003cspan\u003e10KA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003eTotal discharge current (8\/20 µs) [(DC+\/DC-) --\u0026gt; PE] (Itotal)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"211\"\u003e\n\u003cp\u003e\u003cspan\u003e30KA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003eTotal \u003c\/span\u003e\u003cspan\u003edischarge current (10\/350 µs) [(DC+\/DC-) --\u0026gt; PE] (Itotal)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"211\"\u003e\n\u003cp\u003e\u003cspan\u003e12.5KA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003eNominal discharge current (8\/20 µs) [(DC+\/DC-) --\u0026gt; PE] (Itotal)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"211\"\u003e\n\u003cp\u003e\u003cspan\u003e15KA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003eLightning impulse current \u003c\/span\u003e\u003cspan\u003e(10\/350 µs)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"211\"\u003e\n\u003cp\u003e\u003cspan\u003e6.25KA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003eVoltage protection level (DC+\/DC-) --\u0026gt; PE Up\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"211\"\u003e\n\u003cp\u003e\u003cspan\u003e2.5KV\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003eVoltage protection level (DC+ --\u0026gt; DC-) Up\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"211\"\u003e\n\u003cp\u003e\u003cspan\u003e4.75KV\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003eResponse time  (t\u003c\/span\u003e\u003csub\u003e\u003cspan\u003eA\u003c\/span\u003e\u003c\/sub\u003e\u003cspan\u003e )\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"211\"\u003e\n\u003cp\u003e\u003cspan\u003e≤ 25 ns\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003eOperating state \/ fault indication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"211\"\u003e\n\u003cp\u003e\u003cspan\u003eGreen\/Red\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003eDin rail\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"211\"\u003e\n\u003cp\u003e\u003cspan\u003e35mm DIN rails\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003eDegree of protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"211\"\u003e\n\u003cp\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" width=\"357\"\u003e\n\u003cp\u003e\u003cspan\u003eCertificate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" width=\"211\"\u003e\n\u003cp\u003e\u003cspan\u003eTUV , CE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"ZJ Beny","offers":[{"title":"Default Title","offer_id":37642229153976,"sku":"AC-SA-ZJ-DC-1000 I+II","price":590.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0763\/7835\/products\/unnamed.jpg?v=1607007299"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0763\/7835\/collections\/collection-surge-arrestors-1000.jpg?v=1792422862","url":"https:\/\/www.inverter-warehouse.co.za\/collections\/surge-arrestors-dc.oembed","provider":"Solar \u0026 Inverter Warehouse","version":"1.0","type":"link"}